• Port Size: 1/4 (F) NPT
• Maximum Airflow at 100 PSI: 20 SCFM
• Maximum Working Pressure: 250 PSI
• Working Temperature: 4 to 66 °C
• Working Pressure: 0-125 PSI
• Filtration:
Filter/Regulator: 5 microns
Coalescing Filter: 0.01 micron
• Drain: Manual drain
• Bowl Capacity: 44.4 ml
• Pressure Gauge Port Size: 1/8 (F) NPT
Material(s):
• Bowl: Zinc
• Compact design with space-saving integrated F/R
• Removes water through centrifugal force
• Maintains constant downstream pressure
• Push-pull Adjusting Knob
• High performance filter that removes solid particles and oil and water aerosols greater than 0.01 micron, of which 99.97 % of those between 0.3 and 0.6 Micron
• Automatic drain available
INSTALLATION TIP
Assembly is simple using Allen key style screws and an O-ring
Units can be quickly and easily assembled and disassembled
Available with piping adapters: add suffix .01
The lubricator should be installed within 5 meters of the application
WHERE TO INSTALL A FILTER
Install the filter as far as possible from the compressor to allow the compressed air to cool and water vapors to condense. Removal of water in liquid form is more effective than removing water which is vapor form.
Install the filter closest to the tool and before the lubricator and regulator
Always install the filter with the arrows pointing to the tool or application
WHERE TO INSTALL A REGULATOR
Install the regulator on each pipe where applications and air tools requires different working pressure
Always install the regulator downstream of a filter and upstream of a lubricator
Can be installed vertically or horizontally
Always install regulator with the arrows pointing to the tool or application
WHERE TO INSTALL A LUBRICATOR
Install as close to the tool as possible, within 5 meters or 30 meters for micro-fog type lubricators
Always install downstream of a filter and a regulator
Ensure that the lubricator is easily accessible for filling pneumatic tool oil
Always install with the arrows pointing to the tool or application
• Port Size: 1/4 (F) NPT
• Maximum Airflow at 100 PSI: 20 SCFM
• Maximum Working Pressure: 250 PSI
• Working Temperature: 4 to 66 °C
• Working Pressure: 0-125 PSI
• Filtration:
Filter/Regulator: 5 microns
Coalescing Filter: 0.01 micron
• Drain: Manual drain
• Bowl Capacity: 44.4 ml
• Pressure Gauge Port Size: 1/8 (F) NPT
Material(s):
• Bowl: Zinc
• Compact design with space-saving integrated F/R
• Removes water through centrifugal force
• Maintains constant downstream pressure
• Push-pull Adjusting Knob
• High performance filter that removes solid particles and oil and water aerosols greater than 0.01 micron, of which 99.97 % of those between 0.3 and 0.6 Micron
• Automatic drain available
INSTALLATION TIP
Assembly is simple using Allen key style screws and an O-ring
Units can be quickly and easily assembled and disassembled
Available with piping adapters: add suffix .01
The lubricator should be installed within 5 meters of the application
WHERE TO INSTALL A FILTER
Install the filter as far as possible from the compressor to allow the compressed air to cool and water vapors to condense. Removal of water in liquid form is more effective than removing water which is vapor form.
Install the filter closest to the tool and before the lubricator and regulator
Always install the filter with the arrows pointing to the tool or application
WHERE TO INSTALL A REGULATOR
Install the regulator on each pipe where applications and air tools requires different working pressure
Always install the regulator downstream of a filter and upstream of a lubricator
Can be installed vertically or horizontally
Always install regulator with the arrows pointing to the tool or application
WHERE TO INSTALL A LUBRICATOR
Install as close to the tool as possible, within 5 meters or 30 meters for micro-fog type lubricators
Always install downstream of a filter and a regulator
Ensure that the lubricator is easily accessible for filling pneumatic tool oil
Always install with the arrows pointing to the tool or application